2025-12-12 09:40:42 -05:00
|
|
|
name: Reactor Compartment Ventilation System
|
|
|
|
|
abbrev: RCV
|
|
|
|
|
safety class: II
|
|
|
|
|
functions:
|
|
|
|
|
- Controlling radioactive gaseous release to the environment
|
|
|
|
|
during both normal and emergency (post-LOCA) operation and
|
|
|
|
|
maintenance of a low level of airborne radioactivity in
|
|
|
|
|
the reactor compartment and auxiliary spaces to permit
|
|
|
|
|
entry during normal operation or during both schedule and
|
|
|
|
|
unscheduled shutdown.
|
|
|
|
|
- Removing heat to the environment from sources within the reactor
|
|
|
|
|
compartment
|
|
|
|
|
- Containment purging prior to manned entry for maintenance and/or
|
|
|
|
|
inspection. Containment purging would be accomplished only when
|
|
|
|
|
the reactor is at or below hot shutdown conditions; i.e. decay heat
|
|
|
|
|
system is operating.
|
|
|
|
|
- Provide a source of clean air to the control areas if high
|
|
|
|
|
radioactivity levels are present off ship.
|