Add initial data dict
This commit is contained in:
parent
fb28c6c5c5
commit
36fcb5f260
19 changed files with 784 additions and 116 deletions
|
|
@ -1,13 +1,13 @@
|
|||
- name: Component Cooling Water System
|
||||
abbrev: CCW
|
||||
functions:
|
||||
- >
|
||||
Transfer heat from the following components to the RPSW system by CCW
|
||||
heat exchangers during normal operation, scheduled and unscheduled
|
||||
shutdowns, including hot and cold maintenance, and during refueling.
|
||||
name: Component Cooling Water System
|
||||
abbrev: CCW
|
||||
functions:
|
||||
- >
|
||||
Transfer heat from the following components to the RPSW system by CCW
|
||||
heat exchangers during normal operation, scheduled and unscheduled
|
||||
shutdowns, including hot and cold maintenance, and during refueling.
|
||||
|
||||
* Decay heat removal system heat exchangers
|
||||
* Makeup and purification system letdown heat exchangers
|
||||
* Reactor coolant pump heat exchangers
|
||||
* Control rod drive mechanism cooling jackets
|
||||
* Suppression pool heat exchangers
|
||||
* Decay heat removal system heat exchangers
|
||||
* Makeup and purification system letdown heat exchangers
|
||||
* Reactor coolant pump heat exchangers
|
||||
* Control rod drive mechanism cooling jackets
|
||||
* Suppression pool heat exchangers
|
||||
|
|
|
|||
|
|
@ -1,18 +1,18 @@
|
|||
- name: Reactor Compartment Ventilation System
|
||||
abbrev: RCV
|
||||
safety class: II
|
||||
functions:
|
||||
- Controlling radioactive gaseous release to the environment
|
||||
during both normal and emergency (post-LOCA) operation and
|
||||
maintenance of a low level of airborne radioactivity in
|
||||
the reactor compartment and auxiliary spaces to permit
|
||||
entry during normal operation or during both schedule and
|
||||
unscheduled shutdown.
|
||||
- Removing heat to the environment from sources within the reactor
|
||||
compartment
|
||||
- Containment purging prior to manned entry for maintenance and/or
|
||||
inspection. Containment purging would be accomplished only when
|
||||
the reactor is at or below hot shutdown conditions; i.e. decay heat
|
||||
system is operating.
|
||||
- Provide a source of clean air to the control areas if high
|
||||
radioactivity levels are present off ship.
|
||||
name: Reactor Compartment Ventilation System
|
||||
abbrev: RCV
|
||||
safety class: II
|
||||
functions:
|
||||
- Controlling radioactive gaseous release to the environment
|
||||
during both normal and emergency (post-LOCA) operation and
|
||||
maintenance of a low level of airborne radioactivity in
|
||||
the reactor compartment and auxiliary spaces to permit
|
||||
entry during normal operation or during both schedule and
|
||||
unscheduled shutdown.
|
||||
- Removing heat to the environment from sources within the reactor
|
||||
compartment
|
||||
- Containment purging prior to manned entry for maintenance and/or
|
||||
inspection. Containment purging would be accomplished only when
|
||||
the reactor is at or below hot shutdown conditions; i.e. decay heat
|
||||
system is operating.
|
||||
- Provide a source of clean air to the control areas if high
|
||||
radioactivity levels are present off ship.
|
||||
|
|
|
|||