Some AMS specific stuff, and plant work

This commit is contained in:
Nick Touran 2025-12-01 17:04:45 -05:00
parent 9332337581
commit e474c140ee
30 changed files with 558 additions and 21 deletions

View file

@ -0,0 +1,18 @@
- name: Reactor Compartment Ventilation System
abbrev: RCV
safety class: II
functions:
- Controlling radioactive gaseous release to the environment
during both normal and emergency (post-LOCA) operation and
maintenance of a low level of airborne radioactivity in
the reactor compartment and auxiliary spaces to permit
entry during normal operation or during both schedule and
unscheduled shutdown.
- Removing heat to the environment from sources within the reactor
compartment
- Containment purging prior to manned entry for maintenance and/or
inspection. Containment purging would be accomplished only when
the reactor is at or below hot shutdown conditions; i.e. decay heat
system is operating.
- Provide a source of clean air to the control areas if high
radioactivity levels are present off ship.