name: Reactor Compartment Ventilation System abbrev: RCV safety class: II functions: - Controlling radioactive gaseous release to the environment during both normal and emergency (post-LOCA) operation and maintenance of a low level of airborne radioactivity in the reactor compartment and auxiliary spaces to permit entry during normal operation or during both schedule and unscheduled shutdown. - Removing heat to the environment from sources within the reactor compartment - Containment purging prior to manned entry for maintenance and/or inspection. Containment purging would be accomplished only when the reactor is at or below hot shutdown conditions; i.e. decay heat system is operating. - Provide a source of clean air to the control areas if high radioactivity levels are present off ship.