EPRI ALWR
|
|
=========
|
|
|
|
This page contains some high-level requirements sourced from the EPRI Advanced
|
|
Light Water Reactor Utility Requirements Document :cite:p:`mprAdvancedLightWater99a`
|
|
|
|
.. req:: Passive ALWRs shall not require safety-related AC electric power other than
|
|
inverter supplied AC power for I&C.
|
|
:id: R_ALWR_1
|
|
|
|
.. req:: 72-hours without manual operator action.
|
|
:id: R_ALWR_2
|
|
|
|
For transients and accidents analyzed under the initiating event plus
|
|
single failure Licensing Design Basis assumptions (which include loss of all ac
|
|
power), no credit for manual operator action shall be necessary to meet core
|
|
protection regulatory limits for at least 72 hours following initial indication
|
|
of the need for action (i.e., approximately the time of the initiating event).
|
|
|
|
.. req:: Only simple actions and assistance shall be necessary beyond 72 hours
|
|
:id: R_ALWR_3
|
|
|
|
.. req:: Off-site dose limits shall be maintained for at least 72 hours without
|
|
the need for off-site assistance.
|
|
:id: R_ALWR_4
|
|
|